Plugin allowing to manage the electrical load shedding. The plugin manages 3 types of load shedding :
Smart load shedding requires the Thermostat plugin to operate.
The plugin classifies the thermostats according to their actual temperatures according to the set temperatures.
Shedding will therefore take priority over the parts with the smallest deviation. The gene for the occupants will be less important.
Load shedding is carried out in hierarchical mode on the x actuators. The actuator 1 will be relieved in priority then the 2, 3…
The actuators will be reset in the reverse order of load shedding
Load shedding is performed in rotary mode on the actuators defined for the cyclic mode, then if the power is still greater than the threshold, in hierarchical mode on the others.
Here are the parameters to configure on the plugin :
It is possible to define additional actions in addition to load shedding actions.
It is, for example, possible to send an sms to warn of the beginning and the end of load shedding.
The following parameters can be set:
For now only the official thermostat plugin is managed by intelligent load shedding. It is however possible to use the other 2 load shedding modes with the other thermostats.
Be careful to activate the “Auto” mode on the widget in order to activate load shedding.